BL-210S Transformer Oil BDV Tester (Three Cups) is my company all the scientific and technical personnel, according to national standard GB507-86 line and the DL - 474-4-92, the relevant provisions of the DL/T596-1996, play their own advantages, after a lot of field test and long-term unremitting efforts, carefully research and development of high accuracy, fully digital industrial equipment.Dielectric strength tester for insulation oil as a simple, modelling is beautiful and easy.Due to the use of automatic digital microcomputer control, so high measurement accuracy, strong anti-interference ability, safe and reliable.
Booster Capacity | 1.5kVA |
Booster Speed | 2.0kV/s, 2.5kV/s, 3.0kV/s, 3.5kV/s |
Error: 0.2kV/s | |
The Output Voltage | 0~80kV (Optional) |
Voltage accuracy | ± (2% Reading +2 Words) |
Power Distortion Rate | <1% |
Electrode Gap | Standard 2.5mm |
Number of test | 6 Times (1~6 Times Optional) |
Let stand time | 5 Min (1~9min Optional) |
Dimensions | 670mm×420mm×410mm |
Weight | 38kg |
Environment Temperature | 0~40℃ |
Relative Humidity | ≤85% |
Working Power Supply | AC 220V±20% |
Power Frequency | 50/60Hz |
Power | <200W |
● Dielectric strength tester for insulation oil use large capacity single-chip microcomputer control, stable and reliable work;
● Dielectric strength tester for insulation oil, there is the function of temperature and humidity in time clock display, and is equipped with grounding alarm to remind customers pay attention to safety;
● Dielectric strength tester for insulation oil has a wide range of watchdog circuit to eliminate the phenomenon of crash;
● Multiple operating option, Dielectric strength tester for insulation oil program with GB1986, GB2002 two methods of national standard and custom operation, able to adapt to a variety of different users choice;
● Dielectric strength tester for insulation oil oil cup is made of a special glass casting forming, to eliminate the phenomenon of oil and other interference;
● Dielectric strength tester for insulation oil special high voltage side sampling design for test values directly into the A/D converter, to avoid the error caused in the analog circuit, makes the measurement more accurate;
● Dielectric strength tester for insulation oil inside has over current, over voltage, short circuit protection, and other functions, and with a strong anti-jamming capability, good electromagnetic compatibility.
QQ:2371515083
Phone:+86 135 5410 7427
Tel:+86 027-65279286
Email:marketing@blcd.cc